During destructive control in the RSRI Electronstandart testing center the following tests are used:

  • Mass spectrometry humidity control method (according to OST 11 073.013 and MIL-STD-883H and testing center own method);
  • Visual optical test (after opening the package) (according to OST 11 073.013, OST V 11.0219, GOST 16121 and MIL-STD-883H);
  • Scanning electronic microscopy methods (according to OST 11 073.013, OST 11 14.1012, OST 11.0219 and MIL-STD-883H);
  • Interconnect durability (according to OST 11 073.013, GOST 28578);
  • Die shift (according to OST 11 073.013, GOST 28578);
  • External terminals durability (according to OST 11 073.013, GOST RV).